A.Abdujalil G‘ulomovPHYSICS EDUCATOR9702

9702 · A LEVEL EXPERIMENTAL THINKING · 2025–2027

Paper 5.
Plan. Analyse. Evaluate.

A complete route through experimental design, linearisation, error bars, uncertain gradients and conclusions. Work the examples before opening their solutions.

1 h 15 min · 30 marksPlanning, Analysis and Evaluation

Written assessment · two questions · no laboratory work during the paper.

Paper 3 guidance

Two kinds of experimental reasoning

The first question asks you to design an experiment; the second supplies data to analyse. Both reward connecting a physical model to measurements. An unfamiliar context is manageable if you identify variables, use the supplied relationship and explain how each quantity would be obtained. Do not rely on remembering one standard experiment.

A useful practice allocation is approximately 35 minutes for planning, 35 minutes for analysis and five minutes for checking. Adjust it to the task. This is a study strategy, not an official timing requirement.

Write a method someone else could carry out

  1. State the test. Identify the independent variable, dependent variable, the proposed relationship and constants to determine.
  2. Draw an operational diagram. Label measuring devices, distances, connections and supports; include circuit polarities where relevant.
  3. Explain variation. Say how the independent variable changes, and choose a feasible range that produces a measurable response.
  4. Explain measurement. State instruments, reference points, zero corrections, timing or alignment method and what is recorded.
  5. Control confounders. Name relevant quantities held fixed and explain how each is maintained or monitored.
  6. Improve reliability. Include sensible repeats, mean values and measures that reduce the dominant fractional uncertainty.
  7. Describe analysis. Rearrange the equation, identify both graph axes and explain which gradient/intercept yields the required constant.
  8. Address a real hazard. Couple the hazard to a specific precaution appropriate to this apparatus.

“Measure accurately” is not a method. Replace it with an action: align the scale with the motion, use a fiducial marker, measure a wire at several positions, time several oscillations, or use a sensor suited to the quantity.

Original example: measuring an unknown mass

A light spring obeys T² = (4π²/k)(m + M), where m is an added known mass, M is an unknown effective oscillating mass, and k is spring stiffness. Design a test to determine M and k.

Model plan and reasoning

Clamp the spring securely above a tray, attach the unknown load and add known slotted masses. Use a vertical scale and fiducial marker to identify a consistent equilibrium crossing. For each of at least six suitably spaced safe added masses, displace the load slightly, release without pushing and time 20 complete oscillations. Repeat timings and average; divide by 20 for T. Keep the same spring and unknown load, small amplitude and vertical motion. Allow motion to settle and avoid overstretching the spring.

Plot T² vertically against m horizontally. The gradient G = 4π²/k and intercept C = GM, so k = 4π²/G and M = C/G. Measure known masses with a balance if their nominal values are not sufficiently reliable. A wide safe mass range improves gradient determination; repeats address timing scatter. The model assumes the spring’s effective oscillating mass is included in M and the small oscillations remain approximately harmonic.

Diagram to draw: stand and clamp, vertical spring, labelled unknown load and added masses, metre rule or marker, and a catch tray. A drawing of a spring alone does not specify the measurements.

Turn the equation into a graph

Physical relationshipVertical Y / horizontal XGradient / intercept
T² = 4π²L/gT² / L4π²/g / zero in the ideal model
V = ε − rIV / I−r / ε
y = axⁿln(y/yref) / ln(x/xref)n / log of the consistently normalised coefficient
V = V0e^(−t/RC)ln(V/Vref) / t−1/RC / ln(V0/Vref)
y = a/x² + by / 1/x²a / b

Logs require dimensionless arguments. A heading such as ln(L/cm) means the log of the numerical length expressed in centimetres. The log has no unit. Choose natural or base-10 logs consistently; for a power law either base gives exponent n as the gradient if the same base is used on both axes. For an exponential law, changing the log base changes the gradient conversion.

Quick check

Given y² = Ax + B, which graph gives A directly?

Reveal reasoning

Plot y² against x. Then gradient = A and intercept = B. Plotting y against x would not be linear in general. Units of A are units(y)² divided by units(x).

Transform the uncertainties with the data

If x = (0.500 ± 0.005) m, then x² = 0.250 m² and Δ(x²) ≈ 2xΔx = 0.005 m². For q = 1/x, Δq ≈ Δx/x² = 0.020 m⁻¹, so q = (2.000 ± 0.020) m⁻¹. For u = ln(x/xref), Δu ≈ Δx/|x| = 0.010. These derivative approximations require small uncertainties; use transformed endpoints when asked or when the uncertainty is not small.

With x = 0.500 ± 0.005, the exact reciprocal interval is [1/0.505, 1/0.495], approximately [1.9802, 2.0202] m⁻¹. The slight asymmetry explains why a symmetric uncertainty is an approximation.

Complete the requested table, including absolute uncertainties for derived values where required. Do not copy the raw-variable uncertainty into a squared or logarithmic column unchanged. Put uncertainty units in headings or alongside values consistently; do not attach metres to a logarithm.

Best-fit and worst acceptable lines

Plot the requested transformed data and error bars. The best-fit line represents the central trend. Draw a distinct, labelled steepest or shallowest acceptable straight line that intersects every required error bar (or relevant uncertainty region if both axes have uncertainty). Joining only two extreme tips can produce a line that misses an intermediate bar, so check all points.

Take large gradient triangles on the lines and find Gbest and Gworst from each. Estimate ΔG = |Gworst − Gbest|. Use the corresponding intercept difference for ΔC. If no single straight line is compatible with all the plotted uncertainties, check plotting and transformations, then discuss model inadequacy or underestimated uncertainties; do not quietly ignore a point.

Worked gradient and stiffness

For the spring experiment, Gbest = 4.00 s² kg⁻¹ and Gworst = 4.20 s² kg⁻¹. Thus ΔG = 0.20 s² kg⁻¹, or 5.0%. Since k = 4π²/G, k = 9.87 N m⁻¹ and its approximate fractional uncertainty is also 5.0%, so Δk ≈ 0.49 N m⁻¹. A suitable rounded result is k = (9.9 ± 0.5) N m⁻¹.

Do not divide this gradient difference by two unless the task defines a different uncertainty procedure. Do not use the slope between two raw data points as a replacement for the fitted-line gradient.

Carry units and uncertainty into the conclusion

With C = (0.80 ± 0.08) s² and G = (4.00 ± 0.20) s² kg⁻¹, M = C/G = 0.200 kg. A conservative first-order estimate adds fractional uncertainties: ΔM/M ≈ 0.08/0.80 + 0.20/4.00 = 0.15. Hence M = (0.20 ± 0.03) kg. This treats the supplied estimates conservatively; fitted intercept and gradient can be correlated, so it is not a full statistical regression uncertainty.

If the graph starts away from X = 0, the intercept is still its value at the true zero of X. An axis break or shifted origin changes how you read it. Keep unrounded numbers through the working. Give a final numerical value, uncertainty, unit and physical interpretation, rather than ending at the graph.

For a proposed proportionality, consider both shape and intercept. A straight line with a significant nonzero intercept supports a linear model, not direct proportionality. A large uncertainty does not prove agreement; it may mean the experiment cannot distinguish competing models.

Independent practice

A capacitor experiment gives a gradient of −0.250 ± 0.015 s⁻¹ on ln(V/Vref) against time. The resistor is (10.0 ± 0.2) kΩ. Find C and an approximate conservative uncertainty.

Reveal solution

G = −1/(RC), so C = −1/(RG) = 1/(10 000 × 0.250) = 4.00 × 10⁻⁴ F = 400 μF. Fractional uncertainty ≈ 0.2/10.0 + 0.015/0.250 = 0.080. Thus C = (400 ± 32) μF, or approximately (400 ± 30) μF after sensible rounding. The capacitance is positive; the negative slope describes decay.

Final check

  • The plan explains variation, measurement, controls, repeats, analysis and relevant safety.
  • The graph axes exactly match the rearranged equation.
  • Transformed uncertainties have been calculated and plotted.
  • The worst acceptable line has been checked against every bar.
  • Constants include signs, units, uncertainty and justified rounding.

Apply the method to a Paper 5 and its own mark scheme · Revisit measurement skills