START WITH THE QUESTION
A repeatable experimental routine
Paper 3 is a laboratory assessment, not a test of memorised apparatus descriptions. Read both tasks, identify the quantities to measure, and notice instructions about ranges, repeats and graphs. A useful practice allocation is about one hour per question, adjusted to the tasks; this is a planning suggestion, not a rule from Cambridge.
- Identify what you change, what you measure, and what must stay constant.
- Sketch the arrangement and inspect instruments for zero offsets, resolution and safe operating limits.
- Take a trial reading to check that the dependent change is measurable.
- Prepare a table before collecting the main results.
- Collect a useful spread of readings, then calculate, plot and interpret.
Use the full requested range where safe. Do not invent or “improve” readings to match a theory. If an instrument fails, follow the examination’s assistance procedure; record what you actually observe.
Choose a measurement method that controls uncertainty
Length, diameter and small distances
Read a scale along its normal to reduce parallax. Locate the actual endpoints rather than the edge of a bulky support. For a wire diameter, measure at several positions and orientations with a micrometer, correct a known zero offset, and average appropriate readings. Use the ratchet consistently to avoid compressing the object. For a very small thickness, measuring a stack and dividing by the count reduces the fractional effect of the scale resolution.
Timing oscillations
Time several complete cycles from an identifiable reference crossing in the same direction. If 20 cycles take 24.6 s, T = 24.6/20 = 1.23 s. Repeat the timing and compare the spread. Count complete cycles, not successive extreme positions. A fiducial marker helps define the crossing; a longer total timing reduces the fractional effect of reaction time without removing a systematic timing bias.
Electrical measurements
Connect an ammeter in series and a voltmeter across the component. Check polarity, suitable range and connections before switching on. Switch off between readings when heating would change resistance. A variable resistor can control current; never connect an ammeter directly across a source. Record instrument resolution and any observed zero offset. Keep power below the component’s rating and follow laboratory instructions.
Safety must match the apparatus
Secure clamps and keep suspended masses away from feet. Use a tray or catch for falling objects. Protect eyes where stretched wires or springs can snap. Avoid touching hot components and follow the supplied electrical precautions. “Be careful” is not a control measure: identify the hazard and the concrete action that reduces it.
Make the table auditable
Put the quantity and unit in each heading, for example L / m, t / s and T² / s². Put raw measurements beside derived values so the calculation is traceable. Give raw readings at a precision consistent with the instrument, not arbitrary extra digits from a calculator. Keep unrounded intermediate values for subsequent calculations, then report calculated values to justified significant figures and follow any explicit question instruction.
| L / m | t₁ / s | t₂ / s | Mean t / s | T / s | T² / s² |
|---|---|---|---|---|---|
| 0.400 | 25.4 | 25.2 | 25.3 | 1.265 | 1.60 |
| 0.600 | 31.0 | 31.2 | 31.1 | 1.555 | 2.42 |
These are illustrative values, not a complete dataset: two rows cannot establish a reliable graph. Here T retains guard digits for squaring. A full experiment needs additional appropriately spaced lengths and suitable repeat measurements.
Let the graph test the model
Rearrange the proposed relationship into Y = mX + c before labelling axes. Choose convenient linear scales that use a large fraction of the available grid and cover all data. Plot small, clear crosses or dots; draw a best-fit line representing the trend, not a dot-to-dot path. Do not force the line through the origin unless the task and evidence justify that constraint.
Pendulum example: from gradient to g
T² = (4π²/g)L, so plot T² against L. The gradient has units s² m⁻¹. Select two well-separated points on the fitted line, not necessarily measured points. If they are (0.20 m, 0.82 s²) and (0.80 m, 3.24 s²), m = (3.24 − 0.82)/(0.80 − 0.20) = 4.03 s² m⁻¹. Thus g = 4π²/m ≈ 9.79 m s⁻². The pendulum length is from pivot to bob centre; a constant length offset may produce an intercept.
Show the large gradient triangle, substitutions and units. Read an intercept from a justified line extension or calculate c = Y − mX. An off-zero intercept is evidence to investigate, not permission to redraw the line to the desired answer.
Uncertainty is part of the result
An absolute uncertainty has the quantity’s unit; fractional uncertainty is Δx/|x|. For conservative small-uncertainty propagation, add absolute uncertainties for sums or differences and fractional uncertainties for products or quotients. For a power xⁿ, multiply its fractional uncertainty by |n|. Use the question’s stated instrument assumptions rather than a universal “half a division” rule for every device.
Timing uncertainty carried into T²
If t = (24.6 ± 0.2) s for 20 exactly counted cycles, T = (1.230 ± 0.010) s. Fractional uncertainty in T is 0.2/24.6 = 0.00813. For T² it is approximately 0.0163, so Δ(T²) ≈ 1.5129 × 0.0163 = 0.0246 s². A suitable final result is (1.51 ± 0.02) s² with a one-significant-figure uncertainty.
Repeated readings reveal random scatter. Averaging does not correct a zero error, a wrongly defined length or heat loss. A spread-based uncertainty may be appropriate for repeats; its use must match the data and the task.
Answer the precise relationship asked
If asked whether y is proportional to x, a rising trend alone is insufficient: proportionality means y = kx. With limited readings, calculate k = y/x for each pair and compare using the uncertainty method requested. If a full graph is available, inspect linearity and whether an intercept consistent with zero is supported. State the numerical evidence and a qualified conclusion.
For k₁ = 2.40 ± 0.15 and k₂ = 2.55 ± 0.16, the intervals overlap. That supports consistency within these estimated uncertainties; it does not prove the law for all conditions. Do not substitute a memorised 10% or 20% threshold when the question specifies a different comparison.
Connect a limitation to a practical improvement
| Observed limitation | Why it affects this result | Specific improvement |
|---|---|---|
| Hand timing one short cycle | Reaction-time variation is a large fraction of elapsed time. | Time many cycles with a clear marker; use an appropriate light gate if the arrangement permits. |
| Wire diameter varies along its length | One area estimate may be unrepresentative; A depends on d². | Measure multiple positions and orientations and quantify the spread. |
| Filament warms during readings | Resistance changes while testing the intended relationship. | Reduce current and energising time; allow cooling and monitor temperature where feasible. |
| Only two values of a variable | They cannot reveal curvature or a reliable scatter pattern. | Take additional well-spaced readings over a wider safe range. |
Write limitations you can justify for this experiment. “Human error,” “use better equipment,” and “repeat more” do not explain a mechanism. Repeats help random variation; they do not repair a systematic offset.
Before handing in
- Every requested measurement and calculation is present, with units.
- The table distinguishes raw readings from derived quantities.
- Axes, scales, points, line and gradient triangle can be read clearly.
- The conclusion uses numerical evidence and the requested uncertainty test.
- Each improvement responds to an identified limitation of this setup.
Practise with a Paper 3 and its own mark scheme · Continue to Paper 5